USFDA WHO GMP Guidelines Pharmaceutical Regulations Information about Pharma Quality Managment System Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test

Sunday, November 22, 2009

How to Estimate Glucose By Anthron method

Estimation Of Glucose By Anthron method

Principle: - A very useful method for the colorimetric determination of carbohydrates is based on the reaction of an throne with carbohydrates in the presence of strong H2SO4. The conc. H2SO4 hydrolyses the glycoside i.e. bonds to give monosaccharide which are then a hydrated to give furfural and its derivatives which form complexes with an throne. Furfural reacts with an throne to give a blue-green co lour. The blue green co lour shows an absorption maximum at 8.50nm. This method can be used for the determination of hex uses, aldopentoses and hex agonic acids, either free or present in polysaccharides. The reaction is not suitable when protein containing large amount of Tryptophans are present.

Requirement: -
1) An thrones reagent. [0.2 % an throne in cons. H2SO4.]
2) Standard glucose solution [2 llgm / ml]
3) Distilled water.

Procedure: - Prepare a series of test tubes containing graded amount [0.5 llgm] of glucose solution. Make up the volume to 3ml with distilled water. Add slowly 5ml of an throne reagent [from the burette]. Mix thoroughly and neat the tubes on boiling water bath for 10 mins with a marble on top to prevent loss of water by evaporation. Cool and measure the extinction at 650nm against a reagent blank.




===================================================================

This website is a guide for pharmaceutical manufacturing and for pharmacy students and pharmaceutical regulatory affairs proffesionals and for every one associated with pharmaceutical industry , we recommend you to subscribe to this website by entering your email ID in the box provided so that you will receive our articles as and when our website is udated.

Following are some of articles which;will be useful for you in further understanding of aspects of sterile dosage form manufacturing

Pharmaceutical Validation

Cleen Room Classification

Pharmaceutical Industry

Pharmaceutical Manufacturing

Clinical Trials

Media fill

Regulatory Affairs in Pharmaceutical Industry

No comments:

Pharma Guidelines Most Read

.

Readers Visit Number

This website is Authentic Source of Pharmaceutical Guidelines

This website is Authentic Source of Pharmaceutical Guidelines

Pharma Validations Quality Management System USFDA Guidelines WHO GMP Guidelines New Drug Update





This website consist of detail Information about Pharma Guidelines Pharma Regulatory Affairs USFDA Guidelines WHO Guidelines Pharmaceutical Quality Management System Pharma Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test