USFDA WHO GMP Guidelines Pharmaceutical Regulations Information about Pharma Quality Managment System Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test

Saturday, November 21, 2009

estimate protien biurate method

Estimation of protein by biuret method.

Principle of the test
Uria on heating forms biurate
Biuret gives a violet co lour with alkaline copper sulphate solution. This test is answered in general by substances containing 2 or more peptide linkages. Thus when proteins are prated with biuret reagent a pint to purple co lour is obtained. The intensity of the co lour development is proportional to the no. of peptide linkages, proteins gives a purple-violet co lour, proteases and peptones a pink co lour and peptides a much pale pink. However the test is not absolutely specific for peptide bond since any compound containing two carbonyl group (--CONH2 ), joined through a single atom of mtrogen or carbon also will give a positive test.









Requirements: -
1) std. protein solution ( 5 mg / ml )
2) Bitnet reagent.
3) Sample protein solution.
4) Distilled water.

Procedure: - Prepare a series of test tubes for blank standard and sample solution as follows.

Mix the solution in each test tube thoroughly and maintain the tubes at room temperature for ten minutes. Measure the extinction at 540 nm against the blank.
Plot the graph of extinction against concentration and determine the concentration of protein in the given sample solution by extrapolation.

Preparation of biuret reagent:
Dissolve 3 gms. Of cuso4 5H2o and 9.0 gms of Na-k-fortunate in 500 ml of 0.2 N NaOH. Add 5 mgs of KI and make up the volume to one liter with 0.2 N NaOH solution.

===================================================================

This website is a guide for pharmaceutical manufacturing and for pharmacy students and pharmaceutical regulatory affairs proffesionals and for every one associated with pharmaceutical industry , we recommend you to subscribe to this website by entering your email ID in the box provided so that you will receive our articles as and when our website is udated.

Following are some of articles which;will be useful for you in further understanding of aspects of sterile dosage form manufacturing

Pharmaceutical Validation

Cleen Room Classification

Pharmaceutical Industry

Pharmaceutical Manufacturing

Clinical Trials

Media fill

Regulatory Affairs in Pharmaceutical Industry

No comments:

Pharma Guidelines Most Read

.

Readers Visit Number

This website is Authentic Source of Pharmaceutical Guidelines

This website is Authentic Source of Pharmaceutical Guidelines

Pharma Validations Quality Management System USFDA Guidelines WHO GMP Guidelines New Drug Update





This website consist of detail Information about Pharma Guidelines Pharma Regulatory Affairs USFDA Guidelines WHO Guidelines Pharmaceutical Quality Management System Pharma Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test