USFDA WHO GMP Guidelines Pharmaceutical Regulations Information about Pharma Quality Managment System Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test

Monday, August 10, 2009

SOP PREPARATION AUTOCLAVE LOAD

SOP FOR PREPARATION OF LOAD OF AN AUTOCLAVE
OBJECTIVE :-

The load of the autoclave consists of a Nutrient media, glasswares, gowns

machine parts which needs to be sterilised for the purpose of microbiological use


UNIT OF RESPONSIBILITY : QA Executive and trained QA Assistants


IMPORTANT POINT/ NOTE / PRECAUTIONS :-

1 Ensure that the parts to be sterilised are covered properly for effective sterilization

2 Load the autoclave in such a way to ensure even distribution of the steam in autoclave

3 After the completion of autoclave cycle is over ensure that the steam is released slowly
in order to avoid the back pressure inside the autoclave

4 Ensurer the water level before loading any matrial in the autoclave



PROCEDURE :-

1 The items such as media needs to be prepared as per the directions for use in SOP

for media preparation

2 The media tubes, bottles should be plugged with non absorbant cotton and should be
covered with parchment paper

3 The pertidishes are bundled into the parchment paper

4 The empty bottles are plugged with nonabsorbant cotton and are covered with
parchment paper
5 All the items are then transfered into the autoclaved alongwith the Autoclave indicator
labels after which the autoclave is started
6 Note down the time when autoclave is started
7 Let the pressure and temperature rises to 15lbs pressure & 1210c respectively, and
note the time at which the above parameters are reached
8 Let the unit run for 20 minutes, after complition of sterilisation cycle note down the time and
switch off the autoclave
9 Maintain the record of the load as per attachment Nos

PERSONNEL TO BE REPORTED IN CASE OF NON COMPLIANCE :- QA Executive

FREQUENCY OF OPERATION :- Every load for Sterilization
NO OF ATTACHMENT :- One

RETENTION PERIOD OF RECORDS :- 5 years

This website Guide for pharmacy students pharmacy colleges and pharmacists pharmaceutical companies in health care

Standard operating procedure SOP for microbiology and aseptic techniques

Following are some of articles which will be useful for you in further understanding of aspects of sterile dosage form manufacturing

Pharmaceutical Validation

Cleen Room Classification

Pharmaceutical Industry

Pharmaceutical Manufacturing

Clinical Trials

Media fill

Pharmaceutical companies

Regulatory Affairs in Pharmaceutical Industry


Determination of Phenol coeeficient of a disinfectant

No comments:

Pharma Guidelines Most Read

.

Readers Visit Number

This website is Authentic Source of Pharmaceutical Guidelines

This website is Authentic Source of Pharmaceutical Guidelines




This website consist of detail Information about Pharma Guidelines Pharma Regulatory Affairs Quality Management System Pharma Validations Process Validation Cleaning Validation Equipment Qualification Equipment Process Validation Computer System Validation Sterile Product Manufacturing Guidelines Media fill guideline Aseptic Techniques in Sterile dosage form Clean Room Clean Room Classification Guidelines on Area Qualification HVAC AHU HEPA Filter HEPA Filter integrity testing and leak test